Display
- Two lines with 1.8" (46 mm) high digits, red LEDs; 6 digits per line (-99999 to 999999), with lead zero blanking
Display Intensity
- Eight user-selectable intensity levels
Display Assignment
- Displays lines 1 & 2 may be assigned to process values for Channels A (Ch-A, current), V (Ch-V, voltage), or P (Ch-P, apparent power); toggle between (Ch-A & Ch-V, Ch-A & Ch-P, Ch-V & Ch-P, and Ch-A, Ch-V, & Ch-P); relay set points; max and/or min values for CH-A, Ch-V, or Ch-P; CH-A and units; Ch-V and units; Ch-P and units; or Modbus input. The lower display may also be set to show engineering units or be off, with no display.
Noise Filter
- Programmable from 2 to 199 (0 will disable filter)
Filter Bypass
- Programmable from 0.1 to 99.9% of calibrated span
Recalibration
- All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months.
Max/Min Display
- Max/min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Passwords Restrict Modification
- Pass 1: Allows use of function keys and digital inputs
- Pass 2: Allows use of function keys, digital inputs and editing set/ reset points
- Pass 3: Restricts all programming, function keys, and digital inputs
Non-Volatile Memory
- All programmed settings are stored in non- volatile memory for a minimum of ten years if power is lost.
Power Options
- 85-265 VAC 50/60 Hz, 90-265 VDC, 20 W max
- 12-24 VDC ± 10%, 15 W max. Powered over USB for configuration only.
Fuse
- Required external fuse: UL Recognized, 5 A max, slow blow; up to 6 meters may share one 5 A fuse
Normal Mode Rejection
- Greater than 60 dB at 50/60 Hz
Isolation
- 500 V AC/DC potential allowed between voltage and current input channels. Channels isolated by 3 MΩ impedance 4 kV input/output-to-power line 500 V input-to-output or output- to-P+ supply.
Overvoltage Category
- Installation Overvoltage Category II: Local level with smaller transient overvoltages than Installation Overvoltage Category III.
Environmental
- Storage Temperature Range: -40 to 185° F (-40 to 85° C)
- Relative humidity: 0 to 90% non-condensing
- Operating Temperature Range: -40 to 150° F (-40 to 65° C)
Connections
- Removable and integrated screw terminal blocks accept 12 to 22 AWG wire.
Enclosure
- UL Type 4X, IP65 rated. Polycarbonate & glass blended plastic case, color: gray. Includes four PG11 through-hole conduit openings, with two factory installed PG11, IP68, black nylon threaded hole plugs with backing nuts.
Wall Mounting
- Four (4) mounting holes provided for mounting meter to wall
Pipe Mounting
- Optional pipe mounting kit (PDA6260) allows for pipe mounting. Sold separately. See manual for mounting instructions.
Tightening Torque
- Removable Screw Terminals: 5 lb-in (0.56 Nm)
- Digital I/O and RS485 Terminals: 2.2 lb-in (0.25 Nm)
Overall Dimensions
- 10.63" x 12.59" x 4.77" (270 mm x 319.7 mm x 121.2 mm) (W x H x D)
UL File Number
- UL & C-UL Listed. E160849; 508 Industrial Control Equipment.
USB Connection
- Compatibility: USB 2.0 Standard, Compliant
- Connector Type: Micro-B receptacle
- Cable: USB A Male to Micro-B Cable
- Driver: Microsoft® Windows® XP/Vista/7/8/10
- Power: USB Port